Intraoral scanners in dentistry: Principles, workflow, and clinical applications - A comprehensive review
Intraoral scanners (IOSs) have transformed digital dentistry by enabling accurate, real-time capture of intraoral structures, enhancing patient comfort, reducing clinical time, and minimizing infection risks. Their clinical utility spans prosthodontics, implantology, orthodontics, periodontics, endodontics and pedodontics. Advanced IOS systems now integrate caries detection tools, soft-tissue analysis, and AI-driven tooth segmentation, expanding their diagnostic and planning capabilities. While institutional adoption is limited by data integration challenges, IOSs continue to evolve into multifunctional platforms that optimize dental care delivery and patient communication.
References
- Kihara H, Hatakeyama W, Komine F, Takafuji K, Takahashi T, Yokota J, et al. Accuracy and practicality of intraoral scanner in dentistry: A literature review. J Prosthodont Res. 2020;64(2):109–
- https://doi.org/10.1016/j.jpor.2019.07.010
[Google Scholar] - Duret F. The Optical Impression. Universite Claude Bernard; 1973. https://www.francoisduret.com/thesis/
- Logozzo S, Franceschini G, Kilpelä A, Caponi M, Governi L, Blois L. A comparative analysis of intraoral 3D digital scanners for restorative dentistry. Int J Med Technol. 2008;5(1):1–18. https://doi.org/10.5580/1b90
[Google Scholar] - Hwang HHM, Chou CW, Chen YJ, Yao CCJ. An Overview of Digital Intraoral Scanners: Past, Present and Future- From an Orthodontic Perspective. Taiwanese J Orthod. 2018;30(3):148–62. Https://doi.org/10.30036 / TJO.201810_31(3).0003
- Dhar A. Scanning in Dentistry: A Systematic Review. J Pharm Bioall Sci. 2024;16(Suppl 4):S3074–6.
- Richert R, Goujat A, Venet L, Viguie G, Viennot S, Robinson P, et al. Intraoral Scanner Technologies: A Review to Make a Successful Impression. J Healthc Eng. 2017;2017:8427595. https://doi.org/10.1155/2017/8427595
[Google Scholar] - Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 2010;38(7):553–9.
- Schmidt A, Benedickt CR, Schlenz MA, Rehmann P, Wöstmann B. Accuracy of four different intraoral scanners according to different preparation geometries. Int J Prosthodont. 2021;34(6):756–
- https://doi.org/10.11607/ijp.6233
[Google Scholar] - Nagy Z, Simon B, Mennito A, Evans Z, Renne W, Vág J. Comparing the trueness of seven intraoral scanners and a physical impression on dentate human maxilla by a novel method. BMC Oral Health. 2020;20(1):97. https://doi.org/10.1186/s12903-020-01090-x
[Google Scholar] - Mangano FG, Admakin O, Bonacina M, Lerner H, Rutkunas V, Mangano C. Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study. BMC Oral Health. 2020;20(1):263. https://doi.org/10.1186/s12903-020-01254-9
[Google Scholar] - Acker SR, Hartrick NE. Onboarding Intraoral Scanners and the Digital Workflow in Your Practice. Compend Contin Educ Dent. 2023;44(10):590.
- Michelinakis G, Apostolakis D, Kamposiora P, Papavasiliou G, Özcan M. The direct digital workflow in fixed implant prosthodontics: a narrative review. BMC Oral Health. 2021;21(1):37.
- Joda T, Zarone F, Ferrari M. The complete digital workflow in fixed prosthodontics: a systematic review. BMC Oral Health. 2017;17(1):124.
- Camardella L, Breuning H, de Vasconcellos Vilella O. Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner. J Orofac Orthop. 2017;78(3):211–20.
- Manuelli M, Huanca Ghislanzoni L, Farronato M, Martintoni A, Marcolina M, Lucchese A. Comparison of linear transverse measures between plaster and resin printed digital models. J Biol Regul Homeost Agents. 2018;32:81–5.
- Sfondrini M, Gandini P, Malfatto M, Di Corato F, Trovati F, Scribante A. Computerized Casts for Orthodontic Purpose Using Powder-Free Intraoral Scanners: Accuracy, Execution Time, and Patient Feedback. Biomed Res Int . 2018 Apr 23:2018:4103232. https://doi.org/10.1155/2018/4103232
[Google Scholar] - Alassiry AM. Clinical aspects of digital three-dimensional intraoral scanning in orthodontics - A systematic review. Saudi Dent J. 2023;35(5):437–42. https://doi.org/10.1016/j.sdentj.2023.04.004
[Google Scholar] - Joda T, Gallucci G. The virtual patient in dental medicine. Clin Oral Implants Res. 2014;26(6):725–6. https://doi.org/10.1111/clr.12379
[Google Scholar] - Singh S, Ghalaut P, Dixit P, Divakar S. Prosthodontic rehabilitation of resorbed mandibular ridges using guided all-on-four technique and implant retained overdentures- A case series. Natl J Maxillofac Surg. 2025;16(1):189–94.
- Rathee M, Singh S, Alam M, Jain P, Divakar S. Management of repeated denture fracture through direct metal laser sintering metal reinforced denture. J Clin Diagn Res. 2023;17(3):ZD04–6. https://doi.org/10.7860/JCDR/2023/59227.17587
[Google Scholar] - Rutkūnas V, Gečiauskaitė A, Jegelevičius D, Vaitiekūnas M. Accuracy of digital implant impressions with intraoral scanners. A systematic review. Eur J Oral Implantol. 2017;10(Suppl 1):101–20.
- Caron T, Decup F, Grosgogeat B, Chacun D. The relevance of intraoral scanner (IOS) for periodontal diagnosis: A scoping review. J Dent. 2025;160:105824.
- Strauss FJ, Gil A, Smirani R, Rodriguez A, Jung R, Thoma D. The use of digital technologies in peri-implant soft tissue augmentation - A narrative review on planning, measurements, monitoring and aesthetics. Clin Oral Implants Res. 2024;35(8):922–38.
- Serrano-Velasco D, Martín-Vacas A, Paz-Cortés MM, Giovannini G, Cintora-López P, Aragoneses JM. Intraoral scanners in children: evaluation of the patient perception, reliability and reproducibility, and chairside time-A systematic review. Front Pediatr. 2023;11:1213072.
- Schulz-Weidner N, Gruber M, Wöstmann B, Uebereck CF, Krämer N, Schlenz MA. Occlusal Caries Detection with Intraoral Scanners in Pediatric Dentistry: A Comparative Clinical Study. J Clin Med. 2024;13(4):925. https://doi.org/10.3390/jcm13040925
[Google Scholar] - Tashkandi AK, Jiffri SO, Albalawi RM, Albukhari SA, Mugharbil SA, Yeslam HE. Detection of proximal dental caries in primary teeth with a near-infrared-irradiation-assisted intraoral scanner: an in vitro study. BMC Oral Health. 2025;25(1):270. https://doi.org/10.1186/s12903-025-05629-8
[Google Scholar] - Liberato WF, Barreto IC, Costa PP, de Almeida CC, Pimentel W, Tiossi R. A comparison between visual, intraoral scanner, and spectrophotometer shade matching: A clinical study. J Prosthet Dent. 2019;121(2):271–5. https://doi.org/10.1016/j.prosdent.2018.05.004
[Google Scholar] - Witecy C, Ganss C, Wöstmann B, Schlenz MB, Schlenz MA. Monitoring of Erosive Tooth Wear with Intraoral Scanners In vitro. Caries Res. 2021;55(3):215–24. 154 Elbanna et al. / IP Indian Journal of Conservative and Endodontics 2025;10(3):146-154 https://doi.org/10.1159/000514666
[Google Scholar] - Dhull KS, Nagar R, Mathur P, Shil M, Jain S, Dureha R, Kapoor A. Intraoral Scanners: Mechanism, Applications, Advantages, and Limitations. J Pharm Bioall Sci. 2024;16(Suppl 3):S1929–31.
- Zimmermann M, Mehl A, Mörmann WH, Reich S. Intraoral scanning systems - a current overview. Int J Comput Dent. 2015;18(2):101–29.
- Róth I, Géczi Z, Végh DC, Hegedüs T, Pál A, Hermann P, Schmalzl J. The role of artificial intelligence in intraoral scanning for complete-arch digital impressions: An in vitro study. J Dent. 2025;156:105717. https://doi.org/10.1016/j.jdent.2025.105717
[Google Scholar] - Steinmeier S, Wiedemeier D, Hämmerle CHF, Mühlemann S. Accuracy of remote diagnoses using intraoral scans captured in approximate true color: a pilot and validation study in teledentistry. BMC Oral Health. 2020;20(1):266. https://doi.org/10.1186/s12903-
[Google Scholar] 020-01255-8. - Alghauli MA, Aljohani W, Almutairi S, Aljohani R, Alqutaibi AY. Advancements in digital data acquisition and CAD technology in dentistry: Innovation, clinical impact, and promising integration of artificial intelligence. Clin eHealth. 2025;8:32–52. https://doi.org/10.1016/j.ceh.2025.03.001
[Google Scholar] - Liu CM, Hsu MH, Ng MY, Yu CH. Digital integration in dental education: A novel self-directed learning model using intraoral scanners for tooth preparation training. J Dent Sci. 2025;20(1):639–
- Eggmann F, Blatz MB. Recent Advances in Intraoral Scanners. J Dent Res. 2024;103(13):1349–57. https://doi.org/10.1177/00220345241271937
[Google Scholar] - Joda T, Gallucci GO. The virtual patient in dental medicine. Clin Oral Implants Res. 2015;26(6):725–6. https://doi.org/10.1111/clr.12379
[Google Scholar] - Richert R, Goujat A, Venet L, Viguie G, Viennot S, Robinson P, Farges JC, Fages M, Ducret M. Intraoral Scanner Technologies: A Review to Make a Successful Impression. J Healthc Eng. 2017;2017:8427595. https://doi.org/10.1155/2017/8427595
[Google Scholar]
How to Cite This Article
Vancouver
Elbanna L, Singh S, Kalakota S, Genedy A, Madireddi P, Bhola R. Intraoral scanners in dentistry: Principles, workflow, and clinical applications - A comprehensive review [Internet]. IP Indian J Conserv Endod. 2025 [cited 2025 Oct 14];10(3):146-154. Available from: https://doi.org/10.18231/j.ijce.12422.1897150070
APA
Elbanna, L., Singh, S., Kalakota, S., Genedy, A., Madireddi, P., Bhola, R. (2025). Intraoral scanners in dentistry: Principles, workflow, and clinical applications - A comprehensive review. IP Indian J Conserv Endod, 10(3), 146-154. https://doi.org/10.18231/j.ijce.12422.1897150070
MLA
Elbanna, Latifa, Singh, Sandeep, Kalakota, Sruthi, Genedy, Amira, Madireddi, Prathyusha, Bhola, Ridhi. "Intraoral scanners in dentistry: Principles, workflow, and clinical applications - A comprehensive review." IP Indian J Conserv Endod, vol. 10, no. 3, 2025, pp. 146-154. https://doi.org/10.18231/j.ijce.12422.1897150070
Chicago
Elbanna, L., Singh, S., Kalakota, S., Genedy, A., Madireddi, P., Bhola, R.. "Intraoral scanners in dentistry: Principles, workflow, and clinical applications - A comprehensive review." IP Indian J Conserv Endod 10, no. 3 (2025): 146-154. https://doi.org/10.18231/j.ijce.12422.1897150070