Comparative evaluation of various surface contaminants on the microleakage between 7th and 8th generation bonding agent: An in vitro study


Original Article

Author Details : Mahendra Patel, Krushnangi Yagnik*, Nishtha Patel, Shilpa Shah, Harshvardhan Chaudhary

Volume : 8, Issue : 1, Year : 2023

Article Page : 33-37

https://doi.org/10.18231/j.ijce.2023.006



Suggest article by email

Get Permission

Abstract

Aim: To evaluate, the effect of, various surface contaminants on the microleakage between 7 Generation (G-Bond, GC) and 8 Generation Bonding Agent (G-Premio, GC).
Materials and Methods: Ninety freshly extracted maxillary human premolars were collected for the study. They were randomly divided into two groups (n=45), Group 1-7 Generation and Group 2- 8 Generation. They were further subdivided into 3 sub-groups (n=15): a) Control b) Saliva c) Blood. A Class V cavity was prepared on the buccal surface. Samples of both the groups were applied with bonding agent and according to respective sub-group were contaminated with saliva and blood, before curing the bonding agent, then restored with Composite material. The samples were subjected to thermocycling and prepared for dye immersion. Samples were immersed in 2% Methylene Blue dye for 24 hours and later sectioned buccolingually. Each half of the buccolingually sectioned samples was observed under stereomicroscope under the power of 10x and 40x.
Statistical analysis used: Result was obtained using the Chi Square Test.
Results: In Group 1, minimum microleakage is observed in control group, and maximum in those contaminated with blood. In Group 2, maximum microleakage is observed in samples contaminated with blood and the microleakage in samples of control group and those contaminated with saliva is almost same and less than that observed in blood.
Conclusion: 8 Generation shows better performance than 7 Generation Bonding Agent.
Key Message: Contamination from blood and saliva, during bonding leads to a grave outcome of microleakage, during restoration with composite. But, with newer generation of bonding agents, it seems to be a ray of hope at the dawn of preventing microleakage to quite an extent.
 

Keywords: 7 th and 8 th Generation Bonding Agent, Blood, Contaminants, Microleakage, Saliva


How to cite : Patel M, Yagnik K, Patel N, Shah S, Chaudhary H, Comparative evaluation of various surface contaminants on the microleakage between 7th and 8th generation bonding agent: An in vitro study. IP Indian J Conserv Endod 2023;8(1):33-37


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 24-03-2023

Accepted : 12-04-2023


View Article

PDF File   Full Text Article


Copyright permission

Get article permission for commercial use

Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/ 10.18231/j.ijce.2023.006


Article Metrics






Article Access statistics

Viewed: 552

PDF Downloaded: 151