A comparative evaluation of fracture resistance of three recent composite systems in Class II mesio occluso distal cavities - An in vitro study


Original Article

Author Details : Bindu Madhavi Gosala*, Sandya Rani Kollabathula, Mounika Anukolu, Ramakrishna Raju Kanumuri

Volume : 9, Issue : 2, Year : 2024

Article Page : 58-61

https://doi.org/10.18231/j.ijce.2024.013



Suggest article by email

Get Permission

Abstract

Background: Though composite resins have received popularity as restorative materials because of their physical properties, there was a dearth in the research about fracture resistance among recently emerged composite systems including Tokuyama Estelite Sigma Quick, Admira Fusion, and Beautifil II LS nanohybrid composite systems.
Aim: To compare and evaluate the fracture resistance of maxillary premolars with class II mesio occluso distal cavities restored with Tokuyama Estelite Sigma Quick, Admira Fusion, and Beautifil II LS nanohybrid composite systems.
Materials and Methods: Current invitro research was conducted on 44 intact human premolar teeth- Eleven specimens were kept completely intact for control group (Group G1). Class II MOD cavities were done with high-speed handpiece and under constant irrigation in remaining 33 teeth, Group G2, Group G3, Group G4 were restored with Tokuyama Estelite Sigma Quick (Tokuyama Dental, Tokyo, Japan.), Beautifil II LS (Shofu, Germany.), Admira Fusion (Shofu, Germany.) respectively. SPSS version 20 software to analyse the data; and ANOVA followed by Tukey’s post-hoc analysis to compare the fracture resistance were used.
Results: With a fracture resistance of 1297.27±10.27 N, Group 1 (Control) had highest fracture resistance. Group 4 has the least fracture resistance (Admira Fusion). Every pairwise comparison was significant too.
Conclusion: Among the three materials studied, Beautifil II LS had higher fracture resistance and Admira Fusion had the least fracture resistance.
 

Keywords: Composites, Fracture resistance, Filler, Nano­hybrid, Resins


How to cite : Gosala B M, Kollabathula S R, Anukolu M, Kanumuri R R, A comparative evaluation of fracture resistance of three recent composite systems in Class II mesio occluso distal cavities - An in vitro study. IP Indian J Conserv Endod 2024;9(2):58-61


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 13-03-2024

Accepted : 05-04-2024


View Article

PDF File   Full Text Article


Copyright permission

Get article permission for commercial use

Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.ijce.2024.013


Article Metrics






Article Access statistics

Viewed: 762

PDF Downloaded: 177



Medical Abbreviation List